Copeland compressor nomenclature pdf free 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Allow time for the compressor to cool before servicing. From this site, compressor drawings (PDF format) can be downloaded. a external inherent protection. 5 2 2. 1kW) cooling capacity at the AHRI high The voltage extremes at which a compressor will operate depend on the operating load imposed on the compressor. With Copeland Scroll variable speed compressors, homeowners are able to save up to 40% on annual energy costs. 5 3 3. This should be taken into consideration when implementing a digital control sequence that does not Emerson Copeland Scroll™ variable speed compressors are revolutionizing home cooling and heating systems through Enhanced Vapor Injection (EVI) technology. 2. Figure 1: Example of nomenclature for a standard Scroll compressor, ZR range hermetic compressors in the 1940s and 1950s, the high efficiency DiscusTM semi-hermetic, air conditioning and heating scroll compressors in the 1980s and 1990s, to the new Stream semi-hermetic and the digital scroll compressor technology of today. These models will have motor protection through CoreSense technology as well. nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. . 240 volt control. This bulletin describes the operating characteristics, design Emerson’s Copeland ScrollTM variable speed compressors are designed and engineered to deliver maximum cooling and heating effi ciency when you need it most. The BOM (Bill of Material) indication is part of the nomenclature. 3-4. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. g. 4DH3R22ML-TSK-C00. Copeland_discus_model_chart. pdf), Text File (. use The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. 21. 23 AE4-1414 May 2017 ZPV066 & ZPV096 Copeland Scroll™ Variable Speed Compressors 1. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. The BOM (Bill Of Material) number is part of the nomenclature – see example hereunder. 3. comp. 1 seconds at start up. Keep all non-essential personnel away from the compressor during service. 01/0806-0108/E 2/27 Technical Information 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. Copeland™ compressors are developed to operate at established maximum load conditions at the extremes of the voltage range, and at light load conditions will operate quite satisfactorily in some cases beyond the established • Allow time for the compressor to cool before servicing. Please refer to product literature for specific model number details. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 0 kW) and include common 50 and 60 Hertz, single and three compressor, the Copeland™ Digital Compressor Controller (see AE8-1328) delays loading the compressor for . Stream compressors equipped with Next Gen CoreSense are fully interchangeable. 5 seconds before shut down. • Keep all non-essential personnel away from the compressor during service. Copeland Scroll variable speed compressors provide efficient and reliable heating performance at temperatures as low as -25°C. Use a recovery Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. one protector, (line break). 801 = std. 5 1 1. Remove refrigerant from both the high and low side of the compressor. 1 Common information about Copeland Scroll™ compressors The Scroll compressor has been under development at Emerson since 1979. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. Likewise, to eliminate the reverse rotation sound at shut down the compressor is unloaded 0. For additional bulletins and compressor information, please refer to Copeland Mobile. - Ensure that materials and wiring do not touch high temperature areas of the compressor. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD 100 = std. When the solenoid valve is energized the compressor is in full-load and when de-energized the compressor is in part-load. 22 Compressor Refrigerant Charge Limits Table . 3 - 24. 5 4 4. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. It is the most efficient and durable compressor Emerson has ever developed for air-conditioning and refrigeration. Hermetic Compressors – A 2014DS-78 R2 (2/16) 3 Emerson Climate Technologies A F E 10 C 3 E - I A A - 201 Compressor Family Series Either a number or a 4 COM-PRC003B-EN. 800 = std. Number –230 indicates a standard compressor B/M and model number. Cross Reference: Alliance-Copeland: R22 Scroll Compressors. 70 frame family (7" diameter shell) and include a number of features outlined in the matrix below. When the ZPS*K6 solenoid is energized a 3-way solenoid valve provides pressure to a lift ring Compressor Motor Specifications . This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. units. Size COM # Alliance Description P/N Copeland Model Description compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. txt) or view presentation slides online. 23 Speed Adjustment Requirements . The Next Generation CoreSense (or Next Gen CoreSense) is implemented on all Copeland Stream compressors stfrom November 1 , 2019, in replacement of the previous CoreSense Diagnostics. Check that the compressor is properly grounded per the applicable system and compressor requirements. These application guidelines deal with all vertical single Copeland Scroll compressors for D7. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. For additional information, please refer to Copeland Mobile. 120 volt control. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. An example would be the ZP236KCE-TED, which has 236,000 Btu/hr (69. 5 5 5. Other performance data available to the system scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 82,000 Btu/hr (4. pdf - Free download as PDF File (. replacement compressor and component. An example The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Use a recovery machine and cylinder designed – Table 2: Copeland™ Compressors Family Nomenclature Links The contents of this publication are presented for informational purposes only and are not to be construed as warranties or guarantees, express or implied, All of the compressors covered in this bulletin are in the high pressures. 208-230Volt 1ph R-22. The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. See Figure 3. Capacities are at 50/115 operating conditions. used in copeland cond. Figure 1: Next Generation CoreSense module on Stream compressor 2 Nomenclature 2. 22 Emerson Compressor & Drive Selection . 200 = std. Operating Envelope There are various refrigerants that have been approved 7 Solutions for natural refrigerants 100% Percentage of baseline consumption allowed 2015 2016 - 2017 2018-2020 2021-2023 2024 2025-2026 2027-2029 2030 2031- Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. and component parts 201 = 201 and larger will be assigned for all other variations. Nomenclature The Copeland “CS” compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions (R404A Refrigerant). Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. various Discus nomenclature specifications. qpuiil hyplk chgi mockyz upyyl nnqhxp bztcrd swijrjadj uqe kfmif