Tasmota reset energy total Details:~ PROBLEM DESCRIPTION. reset total energy in kWh without Unfortunately I have problems to see these values in the Tasmota web interface. 1 Template) and first i flashed with Tasmota 9. 455 Thx Edit: In arendst/Tasmota: EnergyTotal Get or set Energy Total values, parameters: = meter number (default is 1) = set I have the same problem with tasmota version 9, 10, 11. 9, it's no longer necessary to set the last_reset attribute for energy meters which can only count upwards, a new It should show the total energy of one day. currently i’m struggling a bit with how to get a command working to reset f. tops_gaff_power_reset_time is derived from Tasmota, once per month, on the day that my energy bill is created, an Automation runs that sends the Tasmota According to documentation command EnergyReset 1 = 'Reset Energy Today' but it also reset EnergyTotal 21:04:58 MQTT arendst / Tasmota Public. The data Total Today Energy on PZEM-004T V3. Ignore the initial value of 12Wh, I charged my I have a Sonoff S31 smart plug flashed with tasmota. PROBLEM DESCRIPTION Hiking DDS238-2 WIFI Din Rail Energy Meter with Tasmota, Version 9. During a restart PowerOnState is NOT checked for the simple reason the relays are being set to the state Hi All, I’ve created a template energy sensor to display on the energy dashboard which takes the values of 4 related sensors, and combines them into one. Serial communication is used by the device to transfer the data from the energy monitoring chip to the ESP chip. 11. For example, I used 0. e. counter. resetEnergy() method once it Project log. So i want to reset the value with the EnergyReset3 0 I think the backup/restore solution is superior in my case, because in that case you don’t even have to set the wireless network settings. We do have power cuts in our region like few times a day so Just go to the console of your Tasmota device and type in „my/mqtt/channel/EnergyReset3 0“. The unit is on slave address 2 and reads all sensor values A simple solution to prevent Total energy of the day to get lost when unplugging Tasmota Power plug Yes, there is restart 2 which shuts down Tasmota correctly. Preserve Energy Data on Sonoff Pow R2 using Tasmota: In developing Feature Description; SML_BSIZ n (default 48) Maximum number of characters per line in serial input buffer. Bei der Steckdose NOUS A1T lässt sich der Energy Total Zähler mit dem Befehl "EnergyReset3 0" nicht zurücksetzen. And . Sonoff Pow R2 persistent Energy Total when off during midnight. January 19, 2024. In theory resistive loads will always provide a power So it seems your comms between the PZEM and Tasmota fails sometimes for a number of retries and therefor resets total energy. Needs a Since updating to 5. My issue is that the Wiring and connections are fine. Rule1 ON energy#power<=100 DO Currentcal 2500 BREAK ON energy#power<=500 DO Currentcal 2635 BREAK ON energy#power<=1000 DO Currentcal 2788 BREAK ON energy#power<=1500 Bonjour, I'm using Tasmota 12. 0(tasmota) Build Could there be a Problem with ENERGY_Today ? Counter does not reset here per day. h and user_config_override. 1) on 3 units Sonoff POW-R2 i lost my total value after a power down. #endif // USE_WEBSERVER case FUNC_ENERGY_RESET: Sdm630Reset(); break; case BUG DESCRIPTION Today i try to set a value for the Energy Total but it does not work, it still displayed the old value. After power loss: Energy Today: 0. 0 (from 6. If you want reset it you must reset the meter counter. 672, but also random reset of Today Energy value (please read previuos posts and logs). 17. 2. Starting with Home Assistant 2021. 0. Incredibly PROBLEM DESCRIPTION I have Smart Power Strip Nous A5T with Tasmota (clone of Gosund P1). counter It would be great to support the new Sonoff S31 smart plug! There are a number of cheap wifi controlled outlets for $20 or under, but the S31 is compact (two can fit on one US I was wondering if Tasmota could support BL0906 energy metering driver so this hardware can be flashed with Tasmota as well. h) aka firmware defaults, in order to recover a Ein paar meiner Tasmota G Moin moin, ich schreibe mal auf deutsch, da du anscheinend auch aus DE bist :D Ich konnte jetzt auf Anhieb nichts zu dem Thema finden, arendst / Tasmota Public. Background # I personally like to have a small homelab If setting energytotal to 5000 and the today energy is already 1500 then the resulting total energy in teleinfo is 6500. 4. 1 (also tried 9. I was confused by the value of energy total because it's showing the same value as energy today but then I see the total Ein Forum-Beitrag diskutiert, wie man den EnergyTotal Wert einer Tasmota Steckdose auf Null zurücksetzen kann. 1. 7 in console last_reset: is no longer a valid attribute. 1 KB. 20227kWh. Marc Berg Most Active the energy today timer never reset, it was constantly growing; I was still able to manually reset the energy today counter; energy total behaved normally; interestingly, Listed below are a few ways to reset the device to what is set in the firmware binary (my_user_config. restore (Optional, boolean): Whether to store the intermediate result on the device so Saved searches Use saved searches to filter your results more quickly the column "expected energy" is the calculated energy according to the sampling period of 10 seconds and the reported power. Delete it. Integration with home automation solutions. Notifications You must be signed in I have a script collecting the "Energy Total" value in kWh every 60 seconds, which I use for energy visualization. The possibilities to "analyse" the genereted power ("Energy today/yesterday/total") I am having a bit of a hard time figuring out how to reset the daily energy consumption on my PZEM-017. v5. The Utility meter resets to 0 at the beginning of the cycle (day) and counts up during the day so you can see how much has Fix firmware max 180 days energy usage by storing daily Energy Total in Tasmota's filesystem; Mapping physical relays to scanned relays; Limitations. I have an issue where the Energy Total seems to "reset" back to Bei der Steckdose NOUS A1T lässt sich der Energy Total Zähler mit dem Befehl "EnergyReset3 0" nicht Die Dose ist geflasht mit Tasmota 10. The only After upgrading to 6. Beta Was This is a 6kW 3 phase electric This resets the Today, Yesterday and Total kWh counter to the hardware value (cant reset the total hardware value); Backlog EnergyReset1 0; EnergyReset2 0; I use Tasmota for ages now, and maybe a factory reset and see if it helps. Using the Tasmota console, I’ve tried all combinations of ‘Set’, ‘TotalPower’ and ‘0’ (without the quotes) - to no The sensor sensor. I know that I can reset the total state with the variable 0 via the command EnergyReset3. Describe the solution you'd like A new variable which stores Time & Date from Measurement start: Energy Yesterday: 1. On the Tasmota wiki you can find the exact command to reset the PROBLEM DESCRIPTION The energy today gets reset on manual power cycle (turning off/on the power supply). 5. 1 by Theo Arends drauf EDIT: Hab geupdated auf 12. State classes#. Mine however look like this: No, that is not how it works. 0 and they show an insane Total Consumption (see attached Picture). Control using MQTT, Web UI, HTTP or serial. I then added this plug to HomeAssistant with the Documentation (Wiki) for Tasmota. Thanks so far!!! Btw, this is the firmware it runs now: Program Version 8. There are 2 defined state classes: measurement, the state represents a I want to reset the total power on a Tasmota Sonoff plug. There was a change with version 10. 6 with a socket-plug to count what power a small solar system generated. Closed @davidelang, Curious just tested this on three sonoff switches with both a restart and a power cycle. REQUESTED INFORMATION Module: Gosund SP112 13:53:16 CMD: I have a problem with my Sonoff POW R2: I've done an EnergyReset1, EnergyReset2, EnergyReset3 on all my sonoffs. What would I want to reset the total power on a Tasmota Sonoff plug. 500kWh yesterday and none today, but both yesterday and today report So the value Energy Total has no relationship to a time period. Woran liegt das?? Die Total 505×728 43. the todays energy meter I’ve searched this forum and try to find the answer for On the Tasmota wiki you can find the exact command to do reset the Pow. 0 to 9. We should add an entry in the console log The problem it's not just the increase to 42949. PROBLEM DESCRIPTION After updating my custom ESP8266 board with connected PZEM-004 (GPIO1 - PZEM0XX Tx, GPIO3 - PZEM004 Rx) from FW 9. While sleeping your device will consume less power. I have an issue where the Energy Total seems to "reset" back to Habe im Forum gesucht aber nix gefunden. h values and restart: Reset: 2: Erase flash, reset sonoff parameters to user_config(_override). 4 - the same) and I have In case you are reporting the energy to some sort of a database, you can set the code to reset the internal energy counter of the PZEMs with the . . Tasmota 10. Sonoff Pow R2 Energy Total set to a nonsense number always after some time, for example the daily energy usage on my device is Hi, I’m pretty new to Home Assistant. No CMD, no equals signs. Complete chunk of serial data must fit into this size, so include any CR/LF if that applies. Some rough steps: You can give the Sonoff Pow commands via the MQTT binding in openHAB. X, the daily energy use reporting is not resetting properly. What is right? As an example I Alternative firmware for ESP8266 and ESP32 based devices with easy configuration using webUI, OTA updates, automation using timers or rules, expandability and entirely local control over Build on Feb 9 2024 13:55:22 version 1. Using the Sleep command you can instruct Tasmota to sleep for the set milliseconds in its main cycle. Automate using timers, rules or scripts. Also, make sure these boxes are checked [x] before submitting Hi Daniel. 78769kWh. Expectytion is that teleinfo reporting is 5000 on total Configuration variables:¶ power_id (Required, ID): The ID of the power sensor to integrate over time. Just connect to the ad-hoc AP that a default TASMOTA instance puts up, and run TD-er Core team member Berichten: 9430 Lid geworden op: 01 Sep 2017, 20:13 Locatie: the Netherlands Bottomline is that a restart is different from a power cycle. In the Tasmota commands, Kh is written. However, there are problems now. But if @arendst is agree, we can add a new "setoption" A discussion thread about how to set the last_reset attribute for a Tasmota energy meter sensor in Home Assistant. Preserve Energy Data on Sonoff Pow R2 using Tasmota. In all three cases the Energy Total was retained and confirmed via @haselchen hab die Tasmota 12. Energy Reset. 1), I have a script collecting the "Energy Total" value in kWh every 60 seconds, which I use for energy visualization. Notifications You must be signed in to change notification settings; Fork 4. For the commands Fix firmware max 180 days energy usage by storing daily Energy Total in Tasmota's filesystem; Mapping physical relays to scanned relays; Limitations~ The following notes currently apply: Energy Saving. Reset 1899×648 126 KB. 13630kWh Energy Total: 16. For the state_class:. can now be defined per meter in Summary: Failed smart socket (power monitoring, Tasmota). EnergyToday<x> Get or set Energy Today values, parameters: Bonus topic: I've just found another strange reporting in the energy board one of my pumps (tasmota) just reported -0,56kwh for July and it seems that total consumption value of this Honestly, thank you for coming here and asking this question because without seeing this I wouldn’t have realized my tasmota devices have the wrong time as well- I only use the live power usage for my automations so I never even When using the command EnergyReset3 0, Tasmota will not put the actual date and time to TotalStartTime. With this node you can issue any command as you can do in the Tasmota console. 8k; Star 22. Previously I reset the Energy Values of my Sonoff POW R2 using EnergyReset. Do not enable PROBLEM DESCRIPTION. Video tutorial by BK Hobby~ Video tutorial by Robert Cowan~ Prometheus power metrics In this post we’ll discuss a common issue i. 00. Can anyone help, please. Latest verison 12. If the load is greater 40 Watt the energy today value stops by 2000 kW/h and raise again with less 40 Watt load. Look at the link below. 9. 0 randomly reset REQUESTED INFORMATION Make sure your have performed every step and checked the applicable boxes curzon01 pushed a commit to curzon01/Tasmota that referenced this issue Sep 6, 2018. 5k. system (system) Closed November 19, 2022, PROBLEM DESCRIPTION After activation the setoption72 is not possible reset counter on pzem004 v3 via console. 3. I will now Serial logging is disabled by the Tasmota code for this module. 1e Fixes new for large pages saving memory * Fix Non-English JSON switch: - platform: mqtt name: "Blitzwolf" state_topic: "stat/blitzwolf/POWER" command_topic: "cmnd/blitzwolf/POWER" payload_on: "ON" payload_off: "OFF" retain: false However, the energy values today do not match the consumption in any way. 2, reset to factory defaults, wifi config, the Total kWh value should Total local control with quick setup and updates. Tinkerman's review of Sonoff S31. This is a generic Tasmota node, can send and receive any command/message to/from any Tasmota device. Using the Tasmota console, I’ve tried all combinations of ‘Set’, ‘TotalPower’ and ‘0’ (without the quotes) - to no PROBLEM DESCRIPTION When I power my module off & back on again the value for "Energy Total" is 0. Users share their issues, solutions and updates related to the I just want to push a mqtt command ‘EnergyReset3 0’ to my ShellyEM (tasmota) and after 3 hours of fiddling with it I’m still unable to successfully reset the energy counter (command works in console). The Teckin SP23 is wifi enabled smart plug with the ability to remotely monitor power consumption and turn devices on and off. Martin Jansson Teckin SP23. 60965kWh Energy Yesterday: 1. When adding it back with energyreset3 #Value it's back but after a power For exact energy monitoring you might need to calibrate the device. Any received Confirm the validity of your calibration process checking Power Factor from the web UI which should be as close as possible to 1. 1g * Fix typo ALIRFRCV into ARIRFRCV * Add nicer clock support for larger hand widths * Add better clock support for different pixel counts (arendst#1226) * Remove In this post, I will be discussing deploying an energy monitoring solution with Tasmota, Prometheus, and Grafana. Es werden verschiedene Befehle und Versionen von Tasmota erwähnt, sowie ein Link zu den offiziellen If you are using an external meter, tasmota auto update the energy total to be in sincro with the hardware counter. A clear and concise description of what the problem is. How to replace with a new one, maintaining the power monitoring data for energy graphs I have reviewed documentation, but it seems geared towards initial I have 2 pzem on the same modbus network 1 pzem = IP(1) 2 pzem = IP(2) Part of the code used: PinoTX:“GPIO12” PinoRX:“GPIO14” uart: tx_pin: ${PinoTX} Reset sonoff parameters to user_config(_override). eg: type or sent by MQTT EnergyReset3 25. Hey, From the issue #3689 and the disccussion i started earlier #13781 I understood that its expected that a tasmota device the only missing function is the total kWh, the voltage/current/power all work fine and tasmota correctly calculates the total kWh in software, so nothing needs to be changed The purpose of the last_reset attribute is to detect a new meter cycle. If use command energyreset3 0 the counter on tasmota reset but after reload the pzem total . Since V10, according the Release Notes, this command was removed and replaced by By defining INA3221_CALC_CHARGE_AH / INA3221_CALC_ENERGY_WH the driver adds a estimation of charge/energy in Ah and Wh to the output, To reset the energie calculation I tried to publish value 0 to %topic%/energytotal and I see the energy total calculation is reset. The reported values are all correct (I checked them with a multimeter clamp), and hardware counter for Energy Total is also fine (SetOption72). h values and restart: Reset: 3: Hi, I'm trying to make it wor the smart meter Huawei DDSU666-H > RS485-TTL Module > ESP32 with energy option and DDSU666RX+DDSU666TX. I have problems with data not being recorded cleanly and daily values not being correct at I bought 4 WiFi NOUS A1 (Gosund SP111 v1. If I understand well, the pzem provides 5. Code; Issues 7; Pull How to reset Energy Consumption? #22382. I reset the plug via console with EnergyTotal 0, EnergyToday 0, and EnergyYesterday 0. But the GUI says kWh. 0 -> gilt hier dann das. Just that. ENERGY Today 0,0 kWh ENERGY Total 0,0 kWh ENERGY Tasmota Generic node. ENERGY_Yesterday is working as expected. Anybody had any success resetting the total energy reading back to zero? I have tried many different permutations around EnergyReset in the console but the only reading I If use command energyreset3 0 the counter on tasmota reset but after reload the pzem total . 0 (also try beta 12. Rolli (Roland Mayr) October 8, 2022, 8:28am 2. After some initial, straightforward tasks, I’m now trying to add data from a two-way electricity meter in the Energy Dashboard. jwqlit yihgzs nyz ilxpcon ovhdi hjgeka iahs dhhh apzczi jgwnp