Show log chassisd juniper. #show syslog messages.

Show log chassisd juniper. last 100 of show log chassisd.


Show log chassisd juniper show system core-dumps show version show system uptime show log messages show log chassisd root@hostname> show chassis alarms no-forwarding. Display the first ten and last ten fabric errors for the FPC or Switch Interface Boards (SIBs). DAEMON-X: Major alarm set (***) *** The alarm can be Fan Tray Failure OR Bottom Fan Tray Failure OR Left Fan Tray Failure OR Top/Bottom Fan Tray Failure. 1H 8. EN_US} Capture the output to a file (in case you have to open a technical support case). System alarms indicate a missing rescue configuration or software license, where valid. 5H 0. ; Do you see node0 and node1 listed under Redundancy Group 0?. KB86974 : Displays a list of previous CLI commands. The command "show log chassisd" shows that it has identified the transceiver Display chassis error information including FPC number, severity of error, number of error occurred, cleared, threshold, and corresponding action. Hello, we are running SRX1500 cluster. #show syslog messages. Also, look for TIME (number of system and user CPU seconds that the process has used) and RES (current amount of resident memory, in kilobytes RIP : Show Commands. The messages indicate each node's health condition and details of the monitored failure. The logs can be similar to any one 2-) Couldn't find any resource about the following chassisd logCan I ask about what missing this VC as there is no alarm on system and chassis? fru_is_present: out of range slot 0 for fpm_get_sys_led: FPM display module missing Without knowing more about your platform, it is tough to give a sensible anser, but if we are dealing with M/T/MX, look in the chassisd logs with "show log chassisd"; there should be some hint about what is causing the problem. netisr 0 1680 root 2 8 -88 120M 16856K nanslp 296:01 0. show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit What output do you see? C hassis cluster is not enabled - Consult KB15650 ; Cluster and Redundancy Group information - Continue with Step 2. show chassis cluster status show chassis cluster statistics show chassis cluster information show log jsrpd show log messages show log chassisd request support information ; Modification History. Look for which process is consuming WCPU (Weighted CPU). The issue seems to be with the register value which stores serial number information on the device getting corrupted which is causing the issue. In some cases, the Flexible PIC Concentrators (FPCs) that are taken offline by using the request chassis fpc slot fpc-slot offline operational-mode CLI command can come online after a configuration commit. 375 test-ptx10008-re0 mgd[16201]: authd_sdb. last 100 of show log chassisd. You can use this command to check the status of chassis cluster nodes, redundancy groups, and failover status. When a failure occurs, the backup device becomes primary and controls all forwarding. And like said in the Symptoms, when any chassisd-related show command is issued, the output returns with the following message: "error: the chassis-control subsystem is not running". Contact Support with the following show command outputs if the issue is seen even after FPC reboot. The range for the cluster-id is 0 through 255 and setting it to 0 is equivalent to disabling cluster mode. Ranging from incorrect interface parameters, prodecure to upgrade to underlying host issues to any detail missing or incorrect in XML of the vMX VM >show log messages | match EEPROM >show log messages | match chassisd >show log messages | match i2c >show log chassisd 2. show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit SUMMARY Use this topic to verify your vJunos-switch configuration and for any troubleshooting information. root@router-VC# run show log messages | grep mastership Q9. This command can be useful for diagnostic purposes. root@srx> show log chassisd Perform a reboot of the FPC during a maintenance window, if the errors do not clear automatically. 1X49-D150. MX240 and MX480 routers can support up to two SCBE2s or SCBEs—four fabric planes on each SCBE make up a total of eight planes. Knowledge Base Back. 2 to 18. root@SRX_Branch> show chassis cluster interfaces Control link 0 name: fxp1 Control link status: Up Fabric interfaces: Name Child-interface Status fab0 ge-0/0/2 down fab0 fab1 ge-9/0/2 down fab1 Fabric link status: down . file archive compress SUMMARY Use this topic to verify your vJunos-router configuration and for any troubleshooting information. 2020-09-26 - Article verified for accuracy. Close search. The chassisd user@qfabric> show log messages Mar 28 18:00:06 qfabric chassisd: QFABRIC_INTERNAL_SYSLOG: Mar 28 18:00:06 ED1486 chassisd: CHASSISD_SNMP_TRAP10: SNMP trap generated: FRU power on (jnxFruContentsIndex 8, jnxFruL1Index 1, jnxFruL2Index 1, jnxFruL3Index 0, jnxFruName PIC: Display trace logs information of the host OS. ; For each Redundancy Group, what is the Status? One node is Primary AND one node is Secondary - Without knowing more about your platform, it is tough to give a sensible anser, but if we are dealing with M/T/MX, look in the chassisd logs with "show log chassisd"; there should be some hint about what is causing the problem. On some platforms, you can even try 'start shell pfe direct fpc0' - see if this give you some output. Display information collected by the J-Insight fault monitoring feature. user@qfabric> show log messages Mar 28 18:00:06 qfabric chassisd: QFABRIC_INTERNAL_SYSLOG: Mar 28 18:00:06 ED1486 chassisd: CHASSISD_SNMP_TRAP10: SNMP trap generated: FRU power on (jnxFruContentsIndex 8, jnxFruL1Index 1, jnxFruL2Index 1, jnxFruL3Index 0, jnxFruName PIC: Collect the show command output. Capture the output to a file. Everything went OK, cluster is working normally, all traffic is passing as it should. The following chassis alarm may be seen: Major FPC X Fan X not spinning; Log Messages / Signatures Examples: root@hostname> show log message / show log chassisd. # root> show system uptime Current time: 2017-06-17 23:55:11 GMT # root> show system license License usage: Licenses Licenses Licenses Expiry Feature name used installed needed Virtual Appliance 1 1 0 2017-06-18 00:00:00 GMT Licenses installed: License identifier: JUNOSXXXXX License version: 4 Software Serial Number: XXXXXXXX Customer ID Display the details of chassis errors. 22 up 454+14:20:04 03:42:36 379 processes: 7 running, 343 sleeping, 1 zombie, 28 waiting Mem: 778M Active, 7813M Inact, 1304M Wired, 440M Buf, 5997M Free Swap: 8192M Total, 8192M Free PID USERNAME PRI NICE SIZE RES STATE C TIME root@qfx5100-48t-r2237# run show log chassisd | match short | last 10 Dec 16 13:07:17 cfg_ddl_chasd_handle_config_option: Found {port, short-reach-mode}: Attribute Config action: DAX_ITEM_UNCHANGED Dec 16 13:07:17 Parsing Element {port, short-reach-mode} Dec 16 13:07:17 ch_sfxpc_short_reach_mode_action : Sending Short reach mode message hru This KB addresses the chassis alarms where FPC's are having major errors along with log message - CHASSISD_FRU_UNRESPONSIVE_RETRY. For a High End series SRX services gateway device: {primary:node0} root@SRX_HighEnd> show chassis cluster interfaces Display a list of all Flexible PIC Concentrators (FPCs) and PICs installed in the router or switch chassis, including the hardware version level and serial number. root@srx> show log messages Check for warning messages before and after the failover. The PIC would still be shown online. AFFECTED PRODUCT SERIES / FEATURES. Feb 10 18: 02: 20 [Alarm SET] Object 75 reason 24 Device FRU PEM 1, reason PEM 1 No Power (FPC0: PEM 1 Not Powered), color 1, slot 1 Alarm id 1258356760. If you use these commands on secondary RE, the output shows a warning message to run the commands on primary RE. show log chassisd: Displays chassis-specific log messages, which may include interface status changes and alarms. Mar 18 17:52:09 CHASSISD_PEM_INPUT_BAD: status failure for power supply 0 (status bits: 0x6); check circuit breaker Mar 18 17:52:14 CHASSISD_PEM_INPUT_BAD: status failure for power supply 0 (status bits: 0x6); check circuit breaker Mar 18 17:52:19 CHASSISD_PEM_INPUT_BAD: status failure for power supply 0 (status bits: 0x6); check 37 is when port isn't opterational. Hi, PFE in Present state can have many reasons. ) You can display this information to What output do you see? C hassis cluster is not enabled - Consult KB15650 ; Cluster and Redundancy Group information - Continue with Step 2. 9326. Once the license expires, any 10G port on the device does not show up in 'show interface terse' . The following log messages may be seen: chas[XXX]: Fan X is NOT spinning correctly The results of tracing and logging operations are placed in files in the /var/log directory. The operational mode commands exist in a hierarchical structure. show system core-dumps >>> See if there are any cores for any Log message - CHASSISD_FRU_OFFLINE_NOTICE - FPC offlined due to unreachable destinations. Yes - Continue with Step 3. Ranging from incorrect interface parameters, prodecure to upgrade to underlying host issues to any detail missing or incorrect in XML of the vMX VM Juniper@Router> show chassis alarms ----- 3 alarms currently active Alarm time Class Description XXXX-XX-XX XX:XX: XX +03 Minor FPC XX Temp Sensor Fail XXXX-XX-XX XX:XX:XX +03 Major FPC Log message - CHASSISD_FRU_OFFLINE_NOTICE - FPC offlined due to unreachable destinations. show log messages show log chassisd | no-more show chassis hardware show chassis fabric fpcs show chassis fabric map show chassis fabric summary show chassis fabric plane show chassis fabric plane-location start shell pfe network fpc{#} show syslog messages show nvram You can obtain information about the sessions and packet flows active on your device, including detailed information about specific sessions. Each list item includes the file permissions, number of links, owner, group, size, modification date, and path and filename. startup_time value: m Jun 21 10:46:13 CHASSISD_UTIL_RW_ERR: Cannot read This KB addresses the chassis alarms where FPC's are having major errors along with log message - CHASSISD_FRU_UNRESPONSIVE_RETRY. Review this log on both nodes. Platforms that apply: EX2300/ EX3400/EX4300/EX4400. This section describes how to configure system logging for a single-chassis system that runs the Junos OS. MX-Series. The cluster-id is the same on both devices, but the node ID must be different because one device is node 0 and the other device is node 1. In the 'show log messages', review the events that occurred at or just before the appearance of the "SECONDARY_TIMEOUT or PRIMARY_TIMEOUT" message. Capture the output to a file (in case you have to open a technical support case). root@QFX10008> show log chassisd Jun 21 10:46:03 CHASSISD_UTIL_RW_ERR: Cannot read hw. 2) Analyze the show command output. 22 up 454+14:20:04 03:42:36 379 processes: 7 running, 343 sleeping, 1 zombie, 28 waiting Mem: 778M Active, 7813M Inact, 1304M Wired, 440M Buf, 5997M Free Swap: 8192M Total, 8192M Free PID USERNAME PRI NICE SIZE RES STATE C TIME To do this, configure each SSH client/terminal emulator to log your session. The steps will push a zipped file from the specified member ID to the primary Operational mode CLI commands enable you to monitor and control the operation of a Juniper Networks device. Also, look for TIME (number of system and user CPU seconds that the process has used) and RES (current amount of resident memory, in kilobytes Aug 5 16:00:04 re0-mx480-Inforelay fpc0 PFE 0: exceeding rate threshold 5, curr/last err_cell (42540/41874) Juniper Support Portal. Expand search. 959 test-mx480 chassisd[5290]: CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(0) labroot@test-ptx10008-re0> show log messages May 25 18:41:05. Let’s see an example. More. In the show log messages file, review the events that occurred at or just before the appearance of the " I2C Failed device: HMC:U65010:MEM EA0 HMC0, group 0x45 address 0x10 " message. root@EX-4300# run show virtual-chassis Virtual Chassis ID: c14c. Analyze the show command output. SRX platform: Collect the following commands below first, then follow the instructions on KB21781: Data to Collect for all configurations if time allows: show log messages show log chassisd request pfe execute target tnp tnp-name [node Hi, PFE in Present state can have many reasons. However, syslog messages without tags cannot be resolved. Log in to the other Virtual Chassis members (backup Routing Engine or Linecards). Article ID KB82931. In the 'show log messages', review the events that occurred at or just before the appearance of the "lmem addr error" message. #exit . A6. lab@qfx> show log chassisd | match "Pno=NON-JNPR" Feb 13 07:32:59 pic_copy_port_info:Got SFP Rev=, Pno=NON-JNPR, Sno=\x178\x0w\x0xx\x03\xxx . Archive the /var/log/ contents:. CHASSISD_VERSION_MISMATCH Error: Focus on spotting the CHASSISD_VERSION_MISMATCH error, as the cause of the issue can vary based on how the upgrade was performed, and the recovery process may also change. ; show system statistics bridge | match mac >>> Check the number of MAC address moves and learning. 2024 Display status information about the installed Flexible PIC Concentrators (FPCs) and PICs. However, the MX240 and MX480 routers have only six active planes. Juniper PN: NON-JNPR . chassisd status is for jtac debug info and you get these messages if port flaps. * show log chassisd show chassis environment cb show interfaces terse show services sessions count show chassis fabric map show chassis fabric plane root@B7_30> show log messages | find snmp | last 300 Dec 29 04:11:12 J2350-B7_30 snmpd[4235]: For example, syslog messages with the tag ALARMD_IFDEV_RTSLIB_FAILURE or CHASSISD_FAN_FAILURE can be deciphered by using the above command. No RMA is required To do this, configure each SSH client/terminal emulator to log your session. At the same time two PSUs from diffrent chassis are not #show log chassisd. To do this, configure each SSH client/terminal emulator to log your session. In the 'show log messages', review the events that occurred at or just before the appearance of the "Unroll TAIL length overflow" message. In a high availability application, use these commands on primary RE. Output of show chassis cluster status: This command might show a normal output despite having a chassisd mismatch. Knowledge Base Back [MX] Chassis alarm: Mix of FAN TRAYS. show log messages show log chassisd start shell pfe network <fpc#> show nvram show syslog messages exit . root> show system processes extensive | match chassisd 1018 root 1 84 0 32472K 16420K RUN 0 193. I shut down the box and loaded the factory default even. show log messages; show log chassisd; start shell network pfe <fpc#> show nvram; show syslog messages; exit Apr 10 18:16:01 chassisd[5415]: CHASSISD_SNMP_TRAP7: SNMP trap generated: Hard Disk Failed (jnxFruContentsIndex 9, jnxFruL1Index 2, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName node0 Routing Engine , jnxFruType 6, jnxFruSlot 0) integrator@VP_mcRNC_MX-2> show log chassisd | last 50 Mar 18 17:12:09 CHASSISD_PEM_INPUT_BAD: status failure for power supply 0 (status bits: 0x6); check circuit breaker Mar 18 17:12:14 CHASSISD_PEM_INPUT_BAD: status failure for power supply 0 (status bits: 0x6); check circuit breaker >show log messages | match EEPROM >show log messages | match chassisd >show log messages | match i2c >show log chassisd 2. trace user utmp wtmp . Specifically, display information about detected errors based on the FRU. There may be some problem with chassis-control daemon response, you can view chassisd and messages log files to sort out the issue by using the commands file show /var/log/chassisd file show /var/log/messages Feb 20 15:29:08 chassisd[5827]: CHASSISD_SNMP_TRAP10: SNMP trap generated: FRU power on (jnxFruContentsIndex 7, jnxFruL1Index 10, jnxFruL2Index 0, jnxFruL3Index 0, jnxFruName FPC: MPC5E 3D 24XGE+6XLGE @ 9/*/*, jnxFruType 3, jnxFruSlot 9, jnxFruOfflineReason 2, jnxFruLastPowerOff 141461675, jnxFruLastPowerOn 141463892) user@hostname> show system processes extensive no-forwarding last pid: 23035; load averages: 1. show log chassisd | last 100 May 14 16:39:58 SCC: pseudo_create_devs_swfab: Skipping creation of swfab1, since fabric presence is set to true May 14 16:39:58 SCC: lcc_detach_interfaces_not_online lcc 1 May 14 16:39:58 CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(3) May 14 16:39:58 This article details how to gather logs or files from most Juniper Networks EX Series and QFX Series devices, which may play a vital role in Root Cause Analysis (RCA). . This section describes the system log messages that identify the Junos OS process responsible for generating the message and provides a brief description of the user@host> show chassis alarms 2 alarms currently active Alarm time Class Description 2020-03-22 17:25:28 Minor FPC 8 Temperature Warm 2020-03-22 17:24:51 Major Fan Tray 1 Failure Syslog Message: Mar 22 17:24:51 send: red alarm set, device Fan Tray 1, reason Fan Tray 1 Failure Collect the following 'show ' command outputs to investigate further. For an Collect the show command output. Display status information about the PIC installed in the specified Flexible PIC Concentrator (FPC) and PIC slot. You can use the show system core-dumps command to show a list of system core files created when the router or switch has failed. Results For example, in the output below, the chassisd PID is 1630. The auto-complete of the command 'show log ?' gets the list of files from /var/log , where the default and user-created (via [system syslog file xx] or any 'traceoptions') are stored Dear Juniper Experts ,We see a very strange alaram from our qfx5110-48s-4c ( 3 chassis - VC ) switches . There are few processes that can log remotely and couple of them are chassisd and eventd. 00 up 0+18:40:43 06:56:39 154 processes: 3 running, 137 sleeping, 14 waiting Mem: 582M Active, 128M Inact, 78M Wired, 253M Cache, 69M Buf, 2196M Free Swap: 8192M Total, 8192M Free 1630 root 2 8 The first file is show log messages , which contain general purpose log messages, and the show log chassisd file, which determines if there are any other hardware chassis failures. This is very useful to see the latest logs in the log file. Generally you should verify the port state/status with: -> show poe interface-> show poe controller . *, Count . Junos OS CLI操作コマンドには、デバイス上の特定のコンポーネントを識別するために使用できるオプションが含まれています。 たとえば、以下のように表示されます。 show interfaces コマンドを使用して、ルーター上のすべてのインターフェイスに関する情報を表示し Analyze show log messages and show log chassisd at the timestamp when the chassis alarms are raised (in Step1), and identify which component is reporting the errors: Fabric or DPC/MPC? For example, in Step 1, the alarms were raised at 2012-09-31 11:06:30, so you need to look for any Fabric Plane (Fchip for SCB) or DPC/MPC related logs at that Juniper Support Portal. RE: PEM 1 Output Failure ,it shows ok ,then failure ,then ok ,then failure. Check uKernel CPU util for all FPCs in VC - request pfe execute command "show threads" target fpc<no> - request pfe execute command "show sched" target fpc<no> Description. Sample log messages and "show chassis log messages" outputs for these events: During such occurrences, the following logs and show chassis outputs can be seen: Jun XX XX:XX:XX XXXX xxxxx chassisd[7393]: CHASSISD_FRU_TO_SNMP_INDEX_ERROR: snmp_fru_to_bidx: fru_name:SIB: fru_type:8 user@host> show log chassisd | grep Alarm Feb 1 09:49:04 CHASSISD_SNMP_TRAP3: ENTITY trap generated: entStateOperDisabled (entPhysicalIndex 70, entStateAdmin 3, cause downtime on the system and must be performed during a Maintenance Window under supervision by JTAC Engineer or a Juniper Expert. In the 'show log messages', review the events that occurred at or just before the appearance of the "LUCHIP TOE Read" message. After the reboot when devices come back, cluster is formed and ge-0/0/X changes to ge-5/0/X like ge-0/0/1 interface Collect the show command output. AFFECTED >show log messages >show log chassisd >show system core-dumps >start shell network pfe <fpc#> #show nvram. Frequently these events help identify the cause. #Log Time set cli timestamp set cli screen-width 200 show ntp associations no-resolve | no-more Show core files on all routers or switches running Junos OS. 4R3. Description. root@B7_30> show log messages | find snmp | last 300 Dec 29 04:11:12 J2350-B7_30 snmpd[4235]: For example, syslog messages with the tag ALARMD_IFDEV_RTSLIB_FAILURE or CHASSISD_FAN_FAILURE can be deciphered by using the above command. 0 Recommend. ; No - Go to Step 5. In the 'show log messages', review the events that occurred at or just before the appearance of the "response packet with a FATAL state is received from HMC" message. Solution. Once I unplug the trensceiver the et-1/0/52 disappears from the output of "show interfaces terse" command. For instance, if the command “show log messages | last 20” is issued, the following output will be shown: root@SRX210> show log messages | last 20 show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit . show log chassisd | last 100 May 14 16:39:58 SCC: pseudo_create_devs_swfab: Skipping creation of swfab1, since fabric presence is set to true May 14 16:39:58 SCC: lcc_detach_interfaces_not_online lcc 1 May 14 16:39:58 CHASSISD_IFDEV_DETACH_FPC: ifdev_detach_fpc(3) May 14 16:39:58 root@hostname> show chassis alarms no-forwarding. show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit . 00% yarrow show route show route extensive/detail show route active-paths. Frequently, these events help identify show interfaces terse | match 1/0/52 et-1/0/52 up down et-1/0/52. (The SRX Series device also displays information about failed sessions. PTX-Series. 04, 0. This article explains the kinds of configuration changes that can lead to this event and how they can bring up an offline FPC. In the 'show log messages', review the events that occurred at or just before the appearance of the "ALARM" message. The solution is to restart the chassisd process by issuing the following command: The Junos system logging utility is similar to the UNIX syslogd utility. These events frequently help identify the cause. {SYSLOGSERVICENOWTOKEN. show log messages show log chassisd show system core-dumps start shell network pfe <fpc#> show nvram show syslog messages exit These are the some commands being used when performing network change or maintenance, depending on the features or services being run in the network. 93% chassisd 1790 root 1 4 0 433M 348M kqread 40. Typically, this is very useful in verification, troubleshooting and comparison between before and after the change. Erdem. Hint: Look for a match on a string to find the timestamp that a switchover occurred. root@hostname> show log message / show log chassisd. Upgrade Decos/Software: Ensure the router is running the latest or fixed Decos Collect the show command output. show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages Analyze the 'show' Juniper Support Portal. root@> show chassis alarms no-forwarding 3 alarms currently active Alarm time Class Description 2024-06-21 00:39:03 UTC Major CB 1 Failure 2024-06-21 00:39:03 UTC Major CB 1 Fabric Chip 0 Failure 2024-06-21 00:39:03 UTC Major CB 1 Fabric Chip 1 Failure root@> show chassis fabric summary no-forwarding 4 Fault 38 minutes, 51 seconds 5 Fault 38 The same log is generated every 5 seconds in the chassisd log file as below. Log Messages / Signatures Examples. The following log messages may be seen: chas[XXX]: Fan X is NOT spinning correctly An MX960 router can support three Enhanced Switch Control Boards (SCBE2s or SCBEs)—two planes on each SCB and make up a total of six fabric planes. startup_time value: m Jun 21 10:46:13 CHASSISD_UTIL_RW_ERR: Cannot read show log messages show log chassisd request execute pfe command "show nvram" target fpc<FPC#> request execute pfe command "show syslog messages" target fpc<FPC#> Note: For line cards MX2K-MPC7/8/9, the default threshold for single-bit correctable ECC errors on PMB DDR memory is increased from 1 to 10 before declaring a minor alarm. 00% rpd 14 root 1 -16 0 0K 16K - 53:35 0. 18, 1. Capture the output to a file (in case you need to open a Technical Service Request). Any 1G port would still continue to function normally. Log in. show log messages show log chassisd show system core-dumps start shell network pfe <fpc#> show nvram show syslog messages exit Once the license expires, any 10G port on the device does not show up in 'show interface terse' . Juniper RMA PEM one week ago 9. ; For each Redundancy Group, what is the Status? One node is Primary AND one node is Secondary - The Chassisd process is shown as high and the Chassisd logs are showing messages for the PIM Slots, which do not have a PIM card; that is the PIM Card is placed in only PIM Slot 2. VT2644 Fan Tray Fan Tray 1 REV 08 740-031521 ACDA6122 Enhanced Fan Tray user@MX960-PE0> show log chassisd | no-more Sep 6 16:52:53 fm_hsl2_add_plane_staggered plane=5 Sep 6 Collect the show command output. chassis. Article is valid and accurate Verify whether the vJunos-switch is running after you install it. So before we enable remote tracing, let’s confirm this: In this case, a single device in the cluster is used to route all traffic while the other device is used only in the event of a failure (see Figure 1). They include a SRX Series Services gateways can be configured to operate in cluster mode, where a pair of devices can be connected together and configured to operate like a single device to provide high availability. The messages indicate each node's health condition and There may be some problem with chassis-control daemon response, you can view chassisd and messages log files to sort out the issue by using the commands file show /var/log/chassisd file show /var/log/messages Display chassis cluster messages. 2024 Description. Recently we performed software upgrade for both nodes in cluster from 15. Display the current status of the Chassis Cluster. show log messages; show log chassisd; start shell network pfe <fpc#> show nvram; show syslog messages; exit . System alarms are preset. Non Juniper/unsupported optics? - request pfe execute command "show sfp list" target fpc<no> - show chassis pic fpc-slot <> pic-slot <> 4. Below are some commands that will help in isolating the issue: show ethernet-switching mac-learning-log >>> See if MAC addresses are getting deleted and relearned very quickly. From the output above, you can see that RPD is at 93% utilization and is in the kqread (kernel queue read) state. startup_time value: m Jun 21 10:46:08 CHASSISD_UTIL_RW_ERR: Cannot read hw. On Junos OS devices, you can view the information about monitoring the SNMP activity and identifying the problems that impact the SNMP performance: List log files, display log file contents, or display information about users who have logged in to the router or switch. In the 'show log messages', review the events that occurred at or just before the appearance of the "PT Protect Log Error" message. root@SRX-650-3# run show log chassisd | last 300 Apr 21 18:23:26 CHASSISD_SNMP_TRAP6: SNMP trap generated: Power Supply failed (jnxContentsContainerIndex 2, jnxContentsL1Index 1, jnxContentsL2Index 0 root@hostname> show chassis alarms no-forwarding. ): FI: Reorder cell timeout - Stream . 5. Verify SFP Approval by Juniper - Juniper recommends that you use only optical transceivers and optical connectors purchased from Juniper Networks with your Juniper Networks device. show log messages show log chassisd start shell pfe network <fpc#> show nvram show syslog messages The same log is generated every 5 seconds in the chassisd log file as below. SRX-Series HE. Every time a commit is done, chassisd is writing in /var/log/chassisd among other things this line: CHASSISD_PARSE_COMPLETE: Using new configuration . 10, 1. It's my first time configuring Juniper devices and I would like to ask some help if you may. a5d7 please provide us the output of show log messages after the testing . You cannot modify them, although you can configure them to appear automatically in the J-Web user interface or CLI. Verify whether the vJunos-switch is running after you install it. . 16386 up down . For more info on status <no>, you should log a ticket with jtac. Syslog message: XMCHIP(. 25% chassisd last 100 of show log chassisd. Sample log messages and "show chassis log messages" outputs for these events: please contact JTAC (Juniper Technical Assistance Cent Modification History 2024-06-25 - Initial Publication 2024-07-29 - Visibility Modified show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit . Knowledge Base Back >show log chassisd >show log messages >show chassis hardware >show chassis fpc pic-status . Power over Ethernet (POE) stops working and voltage injection occurs. For an This example shows how to set up basic active/passive full mesh chassis clustering on a high-end SRX Series device. When configured as a chassis cluster, the two nodes back up each other, with one node acting as the primary device and the other as the secondary device, ensuring stateful The last command will only show the last “x” number of lines in a file. Collect the show command output to help determine the cause of this message. System alarms are software or operating system software related alarms. 02, 0. Symptoms Below are the outputs which shows the problem state. show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit show log messages show log chassisd start shell network pfe <fpc#> show nvram show syslog messages exit . The Juniper Networks Technical Assistance To do this, configure each SSH client/terminal emulator to log your session. Display active system alarms. root@> show chassis alarms no-forwarding 3 alarms currently active Alarm time Class Description 2024-06-21 00:39:03 UTC Major CB 1 Failure 2024-06-21 00:39:03 UTC Major CB 1 Fabric Chip 0 Failure 2024-06-21 00:39:03 UTC Major CB 1 Fabric Chip 1 Failure root@> show chassis fabric summary no-forwarding 4 Fault 38 minutes, 51 seconds 5 Fault 38 show log messages show log chassisd start shell pfe network <fpc#> show nvram show syslog messages Analyze the show command output. This article provides more information about the parity errors that are seen within the KHT block of the TL Chip in the Flexible PIC Concentrator (FPC). 'Status 36' messages are observed. Upgrade Decos/Software: Ensure the router is running the latest or fixed Decos user@hostname> show system processes extensive no-forwarding last pid: 23035; load averages: 1. Collect the show command output. Restart Chassis-Control Process: Restarting the chassis-control process can often resolve the issue: >restart chassis-control gracefully 3. 3. user@host> show chassis alarms 2 alarms currently active Alarm time Class Description 2020-03-22 17:25:28 Minor FPC 8 Temperature Warm 2020-03-22 17:24:51 Major Fan Tray 1 Failure Syslog Message: Mar 22 17:24:51 send: red alarm set, device Fan Tray 1, reason Fan Tray 1 Failure CHASSISD_VERSION_MISMATCH Error: Focus on spotting the CHASSISD_VERSION_MISMATCH error, as the cause of the issue can vary based on how the upgrade was performed, and the recovery process may also change. List log files, display log file contents, or display information about users who have logged in to This article describes the scenario when To display a log file stored on a single-chassis system, enter Junos OS CLI operational mode To display component error messages in the chassis daemon (chassisd) log This article captures some of the log messages and chassis alarms that are CHASSISD_POWER_CHECK can be caused by a faulty chassis slot of the There may be some problem with chassis-control daemon response, you can view chassisd The auto-complete of the command 'show log ?' gets the list of files from Analyze show log messages and show log chassisd at the timestamp when the chassis alarms are raised (in Step1), and identify which component is reporting the errors: Fabric or DPC/MPC? Display chassis cluster messages. In the 'show log messages', review the events that occurred at or just before the appearance of the "Enqueue upon free pool empty" message. set cli timestamp show rip overview show rip neighbor show route protocol rip show route advertising-protocol rip <neighbor-address> extensive show route receive-protocol rip <neighbor-address> show rip statistics show route forwarding-table show route resolution unresolved: Logs. In the 'show log messages', review the events that occurred at or just before the appearance of the "FI Link sanity checks" message. 3. 2 Seconds in Juniper EX family (MX 4 seconds). show system core-dumps show version show system uptime show log messages show log chassisd Sample log messages and "show chassis log messages" outputs for these events: During such occurrences, the following logs and show chassis outputs can be seen: Jun XX XX:XX:XX XXXX xxxxx chassisd[7393]: CHASSISD_FRU_TO_SNMP_INDEX_ERROR: snmp_fru_to_bidx: fru_name:SIB: fru_type:8 Juniper Support Portal. Aug 23 05:29:53 CHASSISD_RELEASE_MASTERSHIP: Release mastership notification . Juniper Support Portal. >show log messages >show log chassisd >show system core-dumps >start shell network pfe <fpc#> #show nvram. Dec 19 13:22:41. Also observe the STATE of the process. Home; Knowledge; Quick Links. user@router> show system processes extensive last pid: 6753; load averages: 0. this is the chassisd logs at the moment of the crash: Jul 25 11:39:46 Receive SIGHUP Jul 25 11:39:46 sighup_handler do new_config Jul 25 11:39:46 parse_configuration ddl Jul 25 11:39:46 fpc_is_xm_based_fpc: fru pointer is 0x267d000, fn 0x0, i2c-validity: 0 Jul 25 11:39:46 fpc_is_xm_based_fpc: fru pointer is To do this, configure each SSH client/terminal emulator to log your session. Display complete subscriber management database summary information. root@router-name> show interfaces xe-0/0/0 error: device xe-0/0/0 not found root@router-name> show interfaces xe-0/0/1 error: device xe-0/0/1 not found. This article explains the meaning of the "LKUP_ASIC_SINGLE_BIT_ECC (0x40018)" syslog message that may be observed on MX480 Routers or other MX series routers and describes the action that can be taken to clear it. log chassisd cosd dcd dfwc dfwd eccd inventory l2tpd l2tpd_cfg license lmpd mastership messages pf pgmd rdd rtspd sampled smartd. bipjqa hqnr ulelav rmw joxftd scbe uoik xocx mxnglu tohd