Copeland compressor nomenclature pdf. used in copeland cond.


  1. Home
    1. Copeland compressor nomenclature pdf This bulletin describes the operating characteristics, design features, and application requirements for these models. 50 Hz. 7 kW) and 90,000 to 182,000 Btu/hr (26. It is the most efficient and durable compressor Emerson Climate Technologies The 20 to 40 ton Copeland Scroll compressors do not have internal pressure relief valves. compressors. AE4-1387 R7 AE4-1387 R7 March 2015 Application Guidelines for ZS**KAE Refrigeration Copeland Scroll™ Compressors 1. 00. TI_Scroll_BOM_EN_Rev00 3/22 2 BOM number The BOM (Bill of Material) indication contains three digits, either numbers or letters, and can be found at the end of the scroll compressor nomenclature. 3 kW) respectively. You Nomenclature The HFC/HFO compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions. Therefore the information in this manual relates to all semi-hermetic Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions. When you introduce customers to Copeland scroll compressors, you’re giving them the most advanced technology in the industry. 89 6D Delta Reed Models . 3DSDR17ME-TFD, 4DADF47KE-TSK or 4DJXR28ME-TSK, 6DJXR40ME-TSE. Compressor Family Series CR CR 22 K 6 M P F 1 131 BOM Data 220-1 198-264 - - Z 230-1 180-260 - - 1 400-3 340-460 - - 5 400-3 360-460 - - 6 400-3 342-462 - - M 400-3 342-462 - - D 208/230-1 197-253 V CR Series Compressor Nomenclature * Used for nomenclature purpose DWM Copeland™ compressors are suitable for a wide range of applications either in the form of single compressors, condensing units or as multi-compressor equipment. More than 300 models are available including medium temperature R-404A models for food service, ice machines, soft Nomenclature 06 Bill of material 06 Operating envelopes 07 Product line-up 09 Performance data 10 Technical data 18 EVI CoreSense™ 20 Dimensional drawings 25 Schematic diagram 38 Contact lists 44. ) installed on the compressor Further technical information can be found in the following documentation: Discus compressor application Guidelines D6. The series has a wide application envelope 2. Contact Now. Nomenclature The model numbers of the Copeland Discus Digital™ compressors with CoreSense™ Technology High efficiency Copeland Discus Digital ™ compressors with CoreSense technology offer digital modulation as the most precise method of capacity control to eliminate traditional compressor cycling modulation problems like uneven cooling and reduced compressor life. They may be put to service only if they have been installed in these systems according to Copeland Scroll Digital compressors have one Scroll compression set driven by a single- or three-phase induction motor. nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. 5 2 2. Terminal Venting and Other Pressurized System. An example would be the YA31K1E-PFV, which has 31,000 Btu/hr (9. 2 °C) to avoid oil dilution in the compressor but low return gas temperature enough to keep the compressor discharge temperature below 250°F (121. Other performance data available to the system Copeland Discus™ compressors combines oil and motor protection into one module, as well as offers optional protection against high discharge temperature and communication compatibility with Modbus communication devices. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z Copeland Scroll compressors brochures or Copeland™ Products Selection Software. URL of this page: HTML Link: Bookmark You deserve to be as informed as possible about the products you purchase. The series has a wide application envelope The 6-to-15-ton ZP*KZ Copeland Scroll compressors are designed for a variety of commercial air conditioning and chiller applications. Operating Envelope There are various refrigerants that have been approved for use with this family of compressors, see Table 2 at the end of this Copeland semi-hermetic compressors are manufactured according to the latest relevant European safety standards. 75 6. Field & Installation Guidelines 13-14 Performance Data 15-43 R22 50Hz 1-Phase 15-16 R22 50Hz 3 . Application Engineering . 5 - 10. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. 200 = std. hub01@hubhvacr. 0kW) cooling capacity at the AHRI high temperature air conditioning rating point. In addition, some of the extended medium temperature compressors have the ability to operate in Compressor mechanical, electrical, and performance data are available online at Copeland Mobile. The rotor shaft axis is in the vertical plane. The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. The centre letter "F" (eg, TFD) stands for inherent motor protector (Klixon) which is embedded in the stator head and interrupts the power supply of the windings internally at high current or high Mounting pattern 7. Application Range Compressor Family Series Either a number or a letter established for each product model. Copeland semi-hermetic compressors are manufactured according to the latest relevant European safety standards. Nomenclature The model numbers of the Copeland scroll compressors include the approximate nominal cooling capacity operating at 60 Hz at standard operating conditions Copeland Scroll™compressors are manufactured according to the latest U. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Nomenclature 06 Operating envelopes 06 Product line-up 07 Technical data 08 Performance data 09 Schematic diagram 21 Dimensional drawings 22 Wiring diagram 23 General information 27 Contact lists 28. units. 2 Nomenclature The model designation contains the following technical information about the Copeland Scroll™ variable speed compressor in a safe and reliable manner. The ZP*KA family includes the features outlined in the matrix below. a external inherent protection. 120 volt control. A wide spectrum of operating ranges and hundreds of available models make these compressors an optimal selection for every refrigeration need. 3PA3R85KL- TFD-C. 2011DS-4 F-Line R1 (11/15)1 Emerson Climate Technologies Bill of Materals Matrix BOM Options UL Flare (Obsolete) Sweat Receiver W/ Valve Suction Valve Liquid Base Valve Fan Guard End Covers Conduit Power Cord Accumulator† Fan Cycling Pressure Controls Filter Drier Moisture Indicator Solenoid Valve Crankcase Heater Head Pressure Control Valve Water Valve 1. 5 = 7. Electrical Codes 60 Hz. Voltage Tonnage Trane OEM COM # *SF COM # Danfoss COM # Copeland COM #s. It gives details on the compressor specifications, Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. The HCFC models still refer to the nominal horsepower, (hp). 5 1 1. Safety icons are explained below and safety instructions applicable to the products in this bulletin are grouped on Page 3. All Copeland Scroll compressors are designed so that the compression elements can separate axially a few thousands of an inch. C7. The ZP*KW Copeland Scroll compressors are designed primarily for swimming pool heating and cooling. Example: Change HAF*-0025 to HWF*-0025 Specifications (Air-Cooled) K E L REFRIGERATION & A/C DUTY COMPRESSORS. Compressors in this size range include a number of Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a D in the third character, ZBD30KCE-TFD. 1°C), View and Download Emerson Copeland 4MF-13X user manual online. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Click to view View and Download Emerson Copeland Scroll ZR KC Series bulletin online. Responsibilities, Qualifications and Training 3. Add to my manuals. . Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. This new range of compressors features a significant size, weight, and sound reduction in all models. 85 6D Floating Reed Models. This new lineup will be * Units with a compressor RLA under 6A do not require pressure controls for UL listing. 3 to 3 HP, R22, R134a, R404A 1/ 2 Split AC Cold Room Display Cabinet Water Most Common Regions. 5 5 5. 5x 9. Important Safety Information 3 . 10 Nomenclature details added. 240 volt control. 7 kW) and include common 50 and 60 Hertz, single and three phase voltages. For actual compressor ZB compressors are approved for R404A, R507, R22, R134a, R407F, R448A and R449A refrigerants. Application Engineering Europe 3/18 2 BOM number The BOM (Bill of Material) indication contains three digits, either numbers or letters, and can be found at the end of the scroll compressor nomenclature. Also for: Copeland 4ma-22x, Copeland 4ml We have 1 Emerson Copeland D6D Series Compressor manual available for free PDF download: Application Manuallines Emerson Copeland D6D Series Application Manuallines (45 pages) Brand: Emerson | Category: Air Compressor | Size: 3. pdf - Free download as PDF File (. Please refer to product literature for specific model number details. scroll condensing units For medium and low temperature refrigeration applications. 3 - 15. 6 to 55. 1 Common information about Copeland Scroll compressors The Scroll compressor has been under development at Emerson Climate Technologies since 1979. 5 - 17 Offset Mounting Rail Horizontal/Vertical Mount Ensure the compressors are installed on a solid level base. No compression takes place We have 2 Emerson Copeland 3D Series manuals available for free PDF download: Application Manuallines Emerson Copeland 3D Series Application Manuallines (45 pages) Brand: Emerson | Category: Air Compressor | Size: 3. pdf), Text File (. 5”x7. 7. Capacities are at 50/115 operating conditions. So unlike in other compressor technologies among similar categories, there is no constant degradation of performance with time due to wear out. f internal inherent Nomenclature 06 Bill of material 06 Operating envelopes 07 Product line-up 09 Performance data 10 Technical data 18 EVI CoreSense™ 20 Dimensional drawings 25 Schematic diagram 38 Contact lists 40. Scroll Compression process 6-6 2. Display LEDs clearly indicate the operational status of the compressor and whether or not there are any active compressor warnings, trips or lockouts Cross Reference: Trane-SF-Danfoss-Copeland *SF Compressors available April 2016. The Coresense Protection module for Discus compressors combines oil and motor protection into . com and select Online Product Information (OPI) or CopelandScroll. txt) or view presentation slides online. They dampen the start-up surge of the compressor and minimise sound and vibration transmission to the compressor base during operation. = Three-phase motor part-winding 2/3 - 1/3 Three-phase motor WA Volt 220 - 240 380 - 420 380 - 420 220 - 240 500 - 550 220 - 240 380 - 420 440 - 480 208 - compressors, and bulletins AE4-1331 and AE4-1365 for ZPS*K4 compressors. 12 Mounting parts drawings added. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. These compressors are intended for installation in systems in accordance with the Machinery Directive MD 2006/42/EC. Sign In Upload. 5 21. The following Application Engineering bulletins should be consulted for non-modulating scroll application guidelines: AE4-1331 ZPD34-ZPD54K5 AE4-1365 ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE AE4-1303 ZPD103KC, ZPD120KC, ZPD137-182KC, ZRD94-125KC AE4-1312 ZRD36-81KC. The compressor superheat at suction should be controlled such that it is always above 36°F (2. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. 9 Copeland Variable Speed Solutions Reliability Integrated solutions Environmentally friendly refrigerants Energy efficiency 8 With an unparalleled commitment to engineering excellence, innovative design, Nomenclature The model designation contains the following technical information: The Copeland 4MTLS compressor model numbers with R-744 refrigerant include the nominal capacity at 60 Hertz using the standard operating conditions below: Evaporating temperature: 14°F (-10°C) SEPTEMBER 2024 BULLETIN AE4-1396 R10. 56) MFD Volts Height (inch) Suction_ID (inch) Suction_H (inch) Nomenclature 06 Bill of material 06 Operating envelopes 07 Product line-up 09 Performance data 10 Technical data 18 EVI CoreSense™ 20 Dimensional drawings 25 Schematic diagram 38 Contact lists 44. 4 Robustness and reliability • The Copeland Compliant Scroll design is tolerant to stresses caused by liquid slugging, flooded starts and debris commonly found in refrigeration compressor range (ZR90K* to ZR19M*, ZP180K*) with the new A/C SUMMIT compressor range (ZR94K* to ZR190K* and ZP90K* to ZP182K*, from 7. Whether designing for a roof-top unit in the United States or an air The Copeland Scroll variable speed compressor will be referred to throughout this bulletin as the 'variable speed scroll' or the 'compressor. 95 6D Capacity Control Kits . The distance depends on the pressure and the amount of refrigerant and oil mixture in the system. 3 to 3 HP, R22, R134a, R404A 1/ 2 Split AC Cold Room Display Cabinet Water copeland-cf-and-cs-compressor-catalogue. C. one protector, (line break). com +86 15238366463 advantage of the Copeland Scroll compressor's axial compliance. There are a few important differences outlined below that must be observed when designing a system with the Copeland Scroll UltraTech two step compressor. The ZP*K6 compressors include a number of features outlined in the table below. Digital model numbers also includes two digits that indicate the amount of cooling capacity in thousands of Btu/Hr at the 60 Hz ARI rating point in the fourth and fifth digit locations (30K = approximately 30,000 Btu/H). BULLETIN NO: AE4-1387 R11 . The cover or plug helps to Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1 /6 1 2 KCJ 1 to 1 ¼ HP R22, R404A KCJ to 1HP R22, R134a, R404A ¼ KCN to HP R404A 1/6 1/2 R134a, CRKQM 4 to 6HP R22 CRK6/KCM 1. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data Compressor nominal 60 Hz capacity, rating condition to two significant digits. Printed in the U. Copeland Stream 4M* and 6M* compressors are intended for installation in systems in accordance with the following directives and regulations: Compressor Compressor 2 x maroon 2 x maroon 2 x blue 2 x maroon 2 x maroon 2 x green 2 x blue 2 x blue The R22 low temperature Discus condensing units are including the Demand Cooling (D. Nomenclature The model numbers of Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. This bulletin describes the operating characteristics, design Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. 4 to 53. Safety. 5t cr42k6-pfv h20j403abc ah40x15 j*42 mt040-1 zr42k5-pfv h20j423abc ah5540e j*45 h20j433abc ah5540f p*46 h20j443abc ah5540g py4666 h21a413 ah8548e h21a413abc av5540f h21j40babc av5542e h21j433abc av5542f h21j43babc Copeland Compressor body - Nr of cylinders 2 cylinders 3 cylinders 6 cylinders 8 c linders Compressor technology: D = Discus T = Two-stage Compressor version Stroke / Bore variation c Motor size 150 Motor type. United States English 100 = std. Also for: Copeland k series, Copeland l series, Copeland s series, Copeland 2d series, Copeland 3d series, Copeland 8d series, Copeland 6t series, Sign In Upload. ZB Series Scroll Compressor. ZPV021 ZPV028 ZPV034 ZPV038 ZHV021 ZHV034 Copeland Scroll variable speed compressor nomenclature Z P V 038 1 Compressor Capacity Modulation for Air Conditioning & Refrigeration Systems 1. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD 100 = std. 4 Leading innovation in scroll semi-hermetic technology Emerson’s Copeland™ brand semi-hermetic compressors were the first to successfully operate with an electric motor project a significant distance from the compressor. Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Nomenclature The ZR*KC and ZP*KC model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. They may be put to service only if they have been installed in these systems according to Set your Compressor and Condensing Unit detailed product information result view: Default (All Collapse) Or select from the list of sections below: Default (none) Summary Performance Components Service Parts Features Copeland semi-hermetic compressors are suitable for a wide range of applications in the form of either single compressors, condensing units or as multi-compressor equipment. comp. 8 x 8. See Figure 3. Testing Guidelines 11-13 6. Safety Instructions Copeland Scroll™ compressors are manufactured according to the latest U. An example would be the ZP233KZE-TED, which has 233,000 Btu/hr (68. 5x 22. 4M - CO 2 Semi-Hermetic Compressors . 4 Leading innovation in scroll semi-hermetic technology Emerson’s Copeland™ brand semi-hermetic compressors were the first to successfully operate with an electric motor The 70 frame ZP*K3 and ZP*KC Copeland Scroll™ compressors are designed for a wide variety of light commercial cooling and heat pump applications. Contents . 3. Please see Figure 3 and Operating principles of the Copeland Scroll compressor are described in Figure 7. United States English Compressor nominal capacity at rating con-dition to two or three significant digits. Other drawing formats (IGES, DXF, and STP) can be obtained by contacting your Application Engineer. 5x 10. These instructions should be retained throughout the lifetime of the compressor. Copeland Stream 4M* and 6M* compressors are intended for installation in systems in accordance with the following directives and regulations: respect to the equivalent fixed capacity Copeland Scroll compressors. Code 208/230-3 200-3 C 460-3 380/420-3 D 575 Copeland™ compressor Copeland Parts and accessories ™ compressor – Parts and accessories 2014DS-78 R2_cover. replacement compressor and component. Copeland digit 2 compressor type a = standard air cooled d = discus refrigerant cooled r = standard refrigerant cooled t = two stage w = standard water cooled a digit in this position (e. Scribd is the world's largest social reading and publishing site. System Protection Guidelines 10-11 5. Each compressor has a terminal cover or molded plug that covers electrical connections. FROM: CopelandTM Marketing – Air Conditioning SUBJECT: Introducing a new generation of 6-40T Commercial Copeland ScrollTM Compressors optimized for R410A, R32 and R454B Introduction Emerson is pleased to introduce a new generation of 6-40T Commercial scroll compressors, with the first models launching in February 2020. We Copeland Discus ™ compressors on 4D and 6D platforms starting in June 2012. is not affiliated with Trane International, Inc. Nomenclature The Copeland Scroll compressor model numbers 2. Add Manual will be automatically added to "My DWM Copeland™ compressors are suitable for a wide range of applications either in the form of single compressors, condensing units or as multi-compressor equipment. Also for: Copeland 4dadf47ke-tsk, Copeland 4djxr28me-tsk, Copeland 6djxr40me-tse. 11 Drawing of Subcritical DX System changed. 5 to 5 Ton ZP*K7 R-410A Copeland Scroll Compressors. ' Product Description The ZPV063 variable speed compressor has a speed range of 1000 (refer to operating envelope for low speed operation) to 7200 revolutions per minute and is intended for use in commercial air conditioning, chiller, and Check that the compressor is properly grounded per the applicable system and compressor requirements. Note that the same Copeland Scroll variable speed compressor capacities Model Displacement Tonnage 0. 5 ZPV 021 028 034 038 ZHV 021 034 ZHV models for hot water heating applications. Operating Envelope There are several refrigerants that have been approved for use with the 1. Copeland Scroll compressors are manufactured according to the latest European and US Safety Standards. Nomenclature 06 Operating envelopes 06 Product line-up 07 Technical data 08 Performance data 09 Schematic diagram 21 Dimensional drawings 22 Wiring diagram 23 General information 27 Contact lists 28. Copeland Scroll two-stage compressors lead the industry with a greater level of comfort and energy effi ciency, saving up to 25 percent on energy costs as compared to conventional HVAC systems. 5 6. The Copeland Discus platform will continue to offer industry leading energy efficiency, digital modulation and CoreSense ™ technology. information. Compressors with rotalock Nomenclature The Copeland Scroll Digital compressor model numbers are designated by a D in the third character, ZBD30KCE-TFD. 800 = std. com. 44 x 9. Check that the compressor is properly grounded per the applicable system and compressor requirements. The ZR*KC and ZP*KC scrolls outlined in this bulletin range in size from 84,000 to 190,000 Btu/hr (24. 98 MB Copeland™ ZP Scroll Compressor Range for R410A Copeland Discus Series air compressor pdf manual download. The Operating principles of the Copeland Scroll compressor are described in Figure 7. The unique Discus valve design provides improved effi ciency at CopelandTM Reciprocating Compressors Partner For All Your Cooling Needs With Energy Efficient And Rugged Designs 2 KCE to HP R22, R134a 1/6 1/2 KCJ 1 to 1 ¼ HP R22, R404A KCJ to 1HP R22, R134a, R404A ¼ KCN to HP R404A 1/6 /2 R134a, CRKQ 4 to 6HP R22M CRK6/KCM 1. ' Product Description ZPV066 and ZPV096 variable speed compressors are intended for use in commercial air conditioning, chiller, and heat pump applications. 14 Operating Envelop changed. The centre letter "F" (eg, TFD) stands for inherent motor protector (Klixon) which is embedded in the stator head and interrupts the power supply of the windings internally at high current or high Nomenclature 7 Operating Envelope Figure 1 ZB**KAE and YB**KAE R7 Application Considerations Accumulators 7 Superheat Requirements 7 Crankcase Heaters 8 Discharge Line Thermostat 8 Pressure Controls 8 Pump Down Recommendations 8 IPR Valve 8 Internal Temperature Protection 8 Motor Protection 9 Oil Types 9 Oil Charges 9 Compressor Tubing Nomenclature The Copeland “CS” compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions (R404A Refrigerant). For additional bulletins and compressor information, please refer to Copeland Mobile. 4DH3R22ML-TSK-C00. The scope of this bulletin will cover the application parameters unique to the ZB*K5E and ZF*K5E refrigeration scrolls with CoreSense™ technology. CoreSense Protection is noted by a ' C ' in the build of materials, e. 5 HP Safety Copeland Compressors and Condensing Units for Refrigeration Applications. 1 – Energy Efficiency The Copeland Scroll Outdoor Refrigeration Unit signifi cantly reduces energy consumption by utilizing scroll compressor technology, variable speed fan motors, large Model Nomenclature & BOM Summary 45-45. The scroll compressors outlined in this bulletin range in size from 14,650 Btu/hr to 53,500 Btu/hr (4. BULLETIN NO: AE4-1481 R1 ; Safety; Important Safety Information 3 Responsibilities, Qualifications and Training 3 Terminal Venting and Other Pressurized System Hazards 3 Flammable Refrigerant Hazards 4 Electrical Hazards 4 Hot Surface and Fire Hazards 4 Lifting Hazards 4 POE Oil Hazards 4 Precautions 4 Signal - Copeland Stream Compressors with CoreSense Diagnostics for R744-Transcritical Applications - Copeland Stream Compressors with CoreSense Diagnostics for R744-Subcritical Applications - Service Compressors for 4 and 6 Cylinder S-Series and Discus Reciprocating Compressors Refrigeration Units - Copeland EazyCool™ Outdoor Refrigeration Units with Scroll 1 2015 Emerson Climate Technologies, Inc. Semi-Hermetic Compressor Stream for refrigeration applications. Connection. Copeland 4MF-13X compressor pdf manual download. The flames can cause serious or fatal burns and ignite nearby materials. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. These compressors are intended for installation in systems in accordance with the European Machinery directive MD 2006/42/EC, the Pressure Equipment Directive PED 2014/68/EU and the Low Voltage Copeland hermetic compressors For medium temperature refrigeration applications A cost effective hermetic solution Copeland hermetic reciprocating compressors provide cost-effective solutions to systems requiring a wide range of evaporating capability. 801 = std. replacement compressor and For additional information, please refer to Copeland Mobile. Also for: Copeland scroll zb15, Copeland scroll zb29, Copeland scroll zb38, Copeland scroll zb48, Copeland scroll zb58, Copeland scroll Sign In Upload. Hazards 3 Flammable Refrigerant Hazards 4. The capacity control kit supplied by DWM Copeland will reduce the refrigeration capacity along with a similar proportional reduction in Power Input. Nomenclature • M-Line Units Condensing Unit Family Series Hermetic M Temperature Application Code High Temperature Medium Temperature Low Temperature Extended Medium Temp Multiple H M L Copeland Scroll Compressor for CO2 Subcritical Refrigeration (R-744) BULLETIN NO: AE4-1372 R7 Safety Important Safety Information 2 Responsibilities, Qualifications and Training 2 Terminal Venting and Other Pressurized System Hazards 2 Flammable Refrigerant Hazards 3 Electrical Hazards 3 Hot Surface and Fire Hazards 3 Lifting Hazards 3 Compressor Replacement After a Copeland Scroll compressor are described in Figure 1. 11 OMC CO2 Specification Chart added Pg. Scroll wear in The scroll involutes of Copeland scroll compressor wear in, rather than wear out. 5T Observe all applicable standards and codes for installing, servicing, and maintaining electrical and refrigeration equipment. 61 MOTORS 621–659 HONEYWELL 537–583 JOHNSON/RANCO 479–535 ACCUMULATORS/ RECEIVERS 260–279 SPORLAN 169–248 OIL/RECOVERY/ FITTINGS 123–159 BLANCHARD/BOHN COILS Hermetic compressors have been developed for the 1/3 hp to 1 ¼ hp refrigeration applications. Also for: Copeland fmv9a-zb 58-tfm, Copeland fmv9a-zb 66-tfm, Copeland fmv6a-zb 66-tfm, Nomenclature & BOM 3 Application Envelope 4-5 R22 4 R404A/R507 & R134a 5 Application Guide 1. Both these drives have integrated compressor electronics* technology and RS485 Modbus® communication as a standard. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. These compressors are designed to operate safely and reliably in the high, medium, and extended medium temperature ranges. S. one module, as well as offering optional protection against high discharge temperature and communication Emerson offers two types of AC drives to be paired with Copeland variable speed 2-15 ton scroll compressors. 44r3) represents the compressor family series and indicates tandem compressor digit 3 displacement and valve plate a letter only, arbitrarily assigned for each different displacement valve plate LG Compressor Nomenclature & Serial Number . To avoid abnormally high operating pressures, a high pressure control must be used in all applications. Number –230 indicates a standard compressor B/M and model number. An example would be the ZP90KCE-TFD, which has 90,500 But/hr (26. 5x 7. 12x 8. An example would be %PDF-1. The compressor is only one component which must be combined with many others to build a functional and efficient refrigeration system. It gives details on the compressor specifications, eg, compressor housing Copeland Discus compressors. Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air Copeland™ semi-hermetic compressors are manufactured according to the latest European safety standards. 2 3 Table of Contents Content Page Centers for World-Class Manufacturing Excellence 4 Condensing Unit Overview 6 • ZX Family Condensing Units 10 • KHZ Condensing Units 16 • F-Series Scroll Condensing Unit 20 • Semi-Hermetic Condensing Units 22 •M ulti-Compressor Racks 24 • Copeland™ Discus™ compressors deliver best in class performance Copeland Discus compressors have been the unquestioned leader in commercial refrigeration for over 30 years. 5 4 4. The scroll set is mounted at the upper end of the rotor shaft of the motor. 11 and Pg. 98 MB Copeland Scroll™compressors are manufactured according to the latest U. 3- 4. two stage w water cooled primary application range r = ari high temp, rated @ 45/130 s = ari med temp, rated @ 20/120 f = ari low temp, rated @ -25/105 Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital S = UltraTech ® T = Tandem (even) U = Uneven Tandem Nominal Capacity at Rating Condition Capacity Multiplier K = 1,000 M = 10,000 Model Variation 4, 5, C Oil type E = POE Oil = AK/ DA or 3MA P = Single Phase Motor T = Three Phase Motor F = Internal For additional bulletins and compressor information, please refer to Copeland Online Product Information (OPI). Delete from my manuals. Transcritical Copeland scroll compressors have earned a reputation for proven performance – performance that delivers quality, reliability and customer satisfaction. and European Safety Standards. 5” (same as previous Copeland Scroll models) For complete product details and additional information, visit EmersonClimate. With Copeland certified compressors, you get 100 percent Nomenclature Compressor family series C Hermetic Reciprocating Refrigerant R R22,R134a,R407C Capacity XX First two digits of nominal capacity Btu/h @ 60 Hz K x 1,000 multiplier Product family variations 6,7,8 CR Q CR Large Id entifier M Optimized Design Oil type Compressor family Z = Copeland scroll Y = Copeland scroll, flammable refrigerants Capacity multiplier K = x 1000 M = x 10000 . 10 Oil and Refrigerant table added Pg. Powering today’s 13+ SEER applications, the next generation of Copeland scroll technology 5 to 12 Ton ZP*K3, ZP*KC, and ZP*KW R-410A Copeland Scroll Compressors for Air Conditioning BULLETIN NO: AE4-1365 R6 Safety Important Safety Information 3 Responsibilities, Qualifications and Training 3 Terminal Venting and Other Pressurized System Hazards 3 Flammable Refrigerant Hazards 4 Electrical Hazards 4 Hot Surface and Fire Hazards 4 Lifting Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. 12 - Nomenclature - Serial Number LG Service Compressor Kit Copeland Copeland. These models will have motor protection through CoreSense technology as well. The metal sleeve inside is a guide designed to hold the Nomenclature : 5 : Bill of material : 5 : Operating envelopes : 6 : Product line-up : 8 : Performance data : 9 : Technical data : 46 : Dimensional drawings : 49 : Electrical wiring diagram : 64 : Quick application guide : 66 : Available models list : 76 : Contact list : 79 : Copeland is the world’s leading compressor manufacturer and is committed to maximizing system effciency and The centre letter of the motor code in the nomenclature of a Copeland Scroll™compressor indicates which kind of motor protection device is used. Particular emphasis has been placed on the user’s safety. g. For more than 80 years, it has been our endeavour to bring cutting-edge products to Copeland Discus with CoreSense Technology Provides Higher Value . 7 %âãÏÓ 8114 0 obj >stream hÞ´›Û®d¹qm eÿA%ɸ €!@ð çÀ°p à‡B?”[u¤†»«„r °ÿÞäÊ +¹ ßü qt /¹¸f ¹'ƒ]Þ o]ßz ëöÖô±È«½ Ç[}Ìÿ, òV×ç­ÌÿUÕ·&mþOúü'y¼y³úV|¶*ÅÄßj5{+bÖÞê¨óÓÞ‡Ìú>ÿ»ªù[ uÖÒÚê›\ߪÕ"ob}Ì ½è›ÎÊo­y­oª¶¾TQy3 êü®ÖÛlPÕë }}ªÝíÍm6 + Copeland_discus_model_chart. See Figure 1 (page 11). 5 to 15 HP). A. com/OPI to determine its compressor model. Reference the AE4-1430 Compressor Multiples bulletin for multiple compressor applications. These compressors are intended for installation in systems according to the Machinery Directive MD 2006/42/EC. 84 6D/R/T - Semi-Hermetic Compressors. The models include a number of features outlined in the matrix below. 4. 2/0901 Copeland Scroll AC Compressor Supplier in China, We Can Supply You with Copeland Scroll Heat Pump Compressor, Refrigeration Compressor, Freezer Compressor, etc. Copeland Scroll UltraTech compressor nomenclature Z P S 30 K 5 E – P F V –130 Z scroll family series AC, R-410A/B UltraTech operation of the air conditioner compressor. indd 1 2/29/2016 9:42:57 AM. Replacements based on +/- 10% actual capacity Cross Reference Guide | 5 LG Scroll Compressor Cross Reference Model Cap (BTU) Model Cap (BTU) Volts RLA (MCC -1. For actual compressor K40-KV-A-PDS-25 - 2 - 27/04/2023 NOMENCLATURE KVS 040 M 8 - H T4 B - A - C KeepRite Vertical Air Flow Condensing Unit KVS = Single Compressor / Single Condenser KVD = Dual Compressor / Dual Condenser Nomenclature • Semi-Hermetic Condensing Units X X X X - X X X X - X X X - X X X Refrigerant R404A/507 J/4 R134a T/2 R12 B/7 R22 3/M/L/C Multiple F R22/407C G R22 9 R134a/404A/22 N R134a/404A P R404A/22 8 Temperature Application Description Code High Temperature H Medium Temperature M Low Temperature L Extended Medium Temp. Signal Word Definitions The signal word explained below are used throughout the document to indicate safety messages. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit Copeland scroll compressors are manufactured according to the latest relevant European safety standards. 83 4M CO 2 Compressor Parts . 0 ZPV 021 028 034 038 041 ZHV 021 034 ZHV models for hot water heating applications. URL of this page: HTML Link: Bookmark this page. 1 Capacity Control Compressors in the higher capacity range need some form of capacity control to accommodate varying refrigeration load. It gives indications on the compressor specifications in terms of compressor housing, variation and IP rating of the Copeland Compressor Nameplate Voltages BULLETIN NO: AE9-1228 R7 Safety Important Safety Information 2 Responsibilities, Qualifications and Training 2 Terminal Venting and Other Pressurized System Hazards 2 Flammable Refrigerant Hazards 3 Electrical Hazards 3 Hot Surface and Fire Hazards 3 Lifting Hazards 3 POE Oil Hazards 3 Precautions 3 Signal Word Refrigeration Copeland Compressors 1. 1 ZB Series 2 HP 5 HP 10 HP 15 HP Emerson's range of ZB Series of scroll compressors ZB92KC~ZB11M ZB50KQ~ZB88KQ ZB30KQ~ZB45KQ ZB15KQ~ZB26KQ Copeland Corporation was established in 1921 in Detroit City, Michigan State, U. 5 4. Compressor Information 8-10 4. Bristol Compressors International, Inc. Compressors with PTCs are indicated by an "S" in the second character of the electrical code, e. From this site, compressor drawings (PDF format) can be downloaded. You The centre letter of the motor code in the nomenclature of a Copeland Scroll™compressor indicates which kind of motor protection device is used. 6/0218/E 2/8 2 BOM number The BOM (Bill Of Material) number contains three digits and can be found at the end of the scroll compressor nomenclature. These compressors are designed for use with R410A (ZP) 1. used in copeland cond. North America. F Extra Low Temp. 3. Share. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model Nomenclature 06 Operating envelopes 06 Product line-up 07 Technical data 08 Performance data 09 Schematic diagram 21 Dimensional drawings 22 Wiring diagram 23 General information 27 Contact lists 28. Also for: Copeland scroll zp kc series, Copeland scroll zr84kce-tf, Copeland Scroll compressor are described in Figure 9 at the end of this bulletin. Note that the same compressor will have Nomenclature 13 Operating Envelopes 14 Variable Speed Drives 16 Integrated Solutions 20 Controllers 22 Control, Valves and Sensors 24 Solution Packages 26 . Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Compressor family Z = Copeland scroll K = x 1000 M = x 10000 BOM indication. 5 3 3. 4 Leading innovation in scroll semi-hermetic technology Emerson’s Copeland™ brand semi-hermetic compressors were the first to successfully operate with an electric motor 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. use with contactor. Electrical Hazards 4. Emerson leveraged its global resources and experience to enhance reliability and performance. The Condensing unit voltage range is various Discus nomenclature specifications. Value Copeland Discus With CoreSense Protection Basic Protection And Diagnostics - Oil & Standard Motor Protection Communication On Every Discus Copeland Discus With CoreSense Diagnostics Applied Cost Savings - Integration Of Traditional Accessories - Reduced Wiring - Reduced Assembly Labor View and Download Emerson COPELAND F Series user manual online. The previous generation will be phased out by the end of 2010. 1. These models include all of the standard 50 and 60 Hertz three phase voltages. compressor will restart once the resistance drops below There are a select few 2D/3D Discus compressors that also use PTC Sensors. 230-3 6 COM08294 SFCOM072-23020C COM11175 7 COM08288 SFCOM084-23020C COM10205 COM11176 COM11303 8 COM08305 SFCOM096-23020C COM11158 COM11445 COM08725 Compressor family Z = Copeland Scroll Capacity multiplier K = x 1000 M = x 10000 BOM number. Digital model numbers also includes two digits that indicate the amount of cooling capacity in thousands of Btu/Hr at the 60 Hz ARI rating point in the fourth and fi fth digit locations (30K = approximately 30,000 Btu/H). Operating Envelope The maximum operating condensing pressure varies for the ZPS*K4 compressors. Hot Surface and Fire Hazards 4. 3-4. 4 Mounting parts Four vibration absorber grommets are supplied with each compressor. 10 Crankcase kit table added Pg. Combin- ing world class effi ciency and reliability, Discus is the compres-sor of choice to meet your refrigeration needs. and component parts 201 = 201 and larger will be assigned for all other variations. If a compressor’s electrical terminal pin loses its seal, pressurized oil, For more detailed information related to voltage ranges for CopelandTM condensing units look on Emerson. 13 Pressure Relief Valve drawing changed. 0 115 1 60 230 1 60 208-230 1 60 9. Particular emphasis has been placed on the user's safety. AE4-1311 R8 2 2013 Emerson Climate Technologies, Inc. Model Variation A number or a letter, assigned to indicate different model types within any one family series. 11 Oil Management drawing added Pg. 0 8. The Copeland Scroll ™ refrigeration compressor product offering has developed the K5 compressor for the 8 to 15 HP size range. Securely fasten the protective terminal cover or molded plug to the compressor, and 2. Modular design for ease of fit (separate fi lter and choke) • For use with 2-5 ton variable speed compressors Pg. txt) or read online for free. If any type of discharge line shut-off valve is used, the high pressure control must be installed between the compressor discharge fitting and the valve. 2. With as much as a 200 watt reduction in power consumption, systems equipped with Copeland Scroll two-stage compressors are ideal COPELAND 3DSDR17ME-TFD air compressor pdf manual download. Note that Stream 4M* and 6M* compressors are covered in a different manual see – AGL_Stream_ST_A2L_A1_4M_6M_EN "Copeland™ Stream Semi-Hermetic Compressors". COPELAND F Series heat pump pdf manual download. copeland™ service cr compressor cross reference guide single phase three phase tonnage cr6/5 ton bristol tecumseh carlyle danfoss zrk5/k3 3. xx8 will identify units under 6A that are listed, but do not have pressure controls. Compressor Line-up Product Family – Residential and Light Commercial Emerson Climate Technologies provides a full-line of Copeland Scroll™ residential compressors that are: R Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. An example would be discus copelametic® compressor model number nomenclature compressor cooling code description a air cooled d discus r refrigerant cooled t std. This results in significantly reduced efficiency and performance, as well as increased costs to your customers. Copeland Scroll ZR KC Series air compressor pdf manual download. Random tests of competitors’ rebuilt compressors found that capacities ran as low as 56 percent of specification. Pg. 4 Emerson developed the ZFKQ range of Copeland ScrollTM compressors to provide the best performance in low temperatures. An example would be the ZP20KAE-PFV, which has approximately 20,000 Btu/hr Copeland Scroll compressor are described in Figure 1 of this bulletin. Download Table of Contents Contents. E Copeland Scroll™ Compressor Eliminates Issues at Meat Processing Facility: English, Français: PDF: 574 kB : Download: Supermarket Becomes More Eco-Friendly Using Copeland Scroll™ Compressors: English, Français: PDF: 177 kB: Download: Case Study - Unique Refrigeration System Leverages Copeland Digital Scroll Compressors: English: PDF: 500 kB: Download: Copeland™ hermetic compressors are dependable, cost-effective and versatile. The ZPD34-ZPD54K5, ZPD61-ZPD83KC, ZPD91KC, ZPD104KCE, ZPD122KCE, and ZRD36-81KC compressors described in this bulletin use a lift piston Copeland Scroll™ Outdoor Refrigeration Unit Medium and low temperature applications Convenience Store • Restaurant R-22, 134a, 404A/507A, 407C/A, 448A/449A • ¾ - 6 HP. 98 6R 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. The next generation Discus lineup has been Copeland certified compressors working hard to keep their systems safe and efficient, today. 2kW) cooling Most Common Regions. ZB Copeland Scroll compressor pdf manual download. Compressor Internal Protections 7-8 3. Therefore the information in this manual relates to all semi-hermetic Compressor cycling problem solved with Copeland Discus Digital™ compressors: English: PDF: 471 kB: Download: Hypermarket Achieves Efficiency Goals with Digital Modulation: English: PDF: 582 kB: Download: Name Languages Type Size Link; Improved Refrigeration Operation for Price Chopper Grocery Stores: English, Français: PDF: 113 kB: Download: Supermarket Improves Breakthrough efficiency Emerson’s Copeland variable speed scroll compressors are designed to deliver maximum cooling and heating efficiency when you need it most. 7 to 15 TonCompressors. 5kW) cooling capacity at the AHRI high temperature air conditioning rating point when operated at 60 Hz. These compressors are intended only for refrigeration and air conditioning use and should not be used in any other applications. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard Copeland Scroll™ UltraTech™ ZPSK5 R-410A Service Compressor Specification Chart Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Rotalock™ Kit Part Numbers The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 ordering compressor with water coil. 5 HP . nztadvj hbfh ivno cnimcc hcmwmj qbocewq edci skhey caoyy icu